The Code Requirements for Motor Disconnects Are Covered in

A listed molded-case circuit breaker. It is important to have a good understanding of these requirements.


Code Q A Lockable Disconnecting Means Ec M

But the 2017 edition of the National Electrical Code at 42231 added wording that the switch or circuit breaker must be within sight from the appliance or is lockable in accordance with 11025 We added the underlining to from the appliance.

. Every motor has to have a disconnecting means and the disconnect has to be within sight of the motor location. There are many major changes in the 2002 National Electrical Code NEC but none will affect more installations than. For example 430102B and B1 state a disconnecting means is required to be located in sight from the motor location and the driven machinery location.

Motor controllers are covered in Part VII and motor disconnecting means are covered in Part IX of Article 430. The disconnect could be a switch or the branch-circuit overcorrect device circuit breaker. The disconnects are usually in the MCC.

A GEC tap must extend from each disconnect and it must be sized no smaller than specified in Table 25066 based on the area of the largest phase conductor. The code requirements for motor disconnects are covered in NEC Article 430 part IX To determine the horsepower rating of a motor that is already installed and in place. As more municipalities accept the 2002 NEC electricians electrical contractors and electrical maintenance personnel working on residential commercial and industrial installations may now be required to provide motor disconnects within sight from the motor.

Within Sight is visible and not more than 50 ft from each other Art. So you can only take credit for the breaker at the main panel as being the disconnecting means if that breaker is within sight of the motor location and is cabable of being locked open. Reference NEC 430102 B.

The disconnecting means for the motor controller andor the motor must be a 430109 A. Section 430102B1 requires a disconnecting means for each motor and it must be located in sight from the motor location and the driven machinery location. Motor disconnecting means shall be within sight of and within 9 m of the motor.

At least one of these disconnects is required to be readily accessible in accordance with 430107 see figure 2. This is significant because a number of sections throughout the Code contain requirements for disconnecting means. Particular requirements for storage water heaters.

Every industrial site Ive been to you hardly see disconnects within sight of the the motor. A listed horsepower-rated motor-circuit switch. Thats not the only disconnect-related change in Art.

The GEC tap must be connected to the common GEC by any of the following methods. Motors of motor-operated appliances shall be provided with overload protection in accordance with Part III of Article 430. The branch-circuit disconnecting means is permitted to serve as the controller for stationary motors of 18 hp or less that are normally left running and constructed to not be damaged by overload or failure to start such as by clock motors.

A disconnecting means is required for each motor and it must be located in sight from the motor location and the driven machinery location 430102B1. Otherwise under the NFPA79200753 the motor disconnect is an isolation device that must be within sight of both the motor and the machinery that might move. They have become an integral part of the motor control circuit as disconnects increasingly offer control functions such as auxiliary contact interface added selector switches and push buttons.

Article 430 requires motors to have a lockable disconnect within sight. Aug 17 2009. How you apply the requirements of 42231 depends on the VA rating and horsepower rating of the appliance.

NEC Article 430 part IX The method of braking in which DC is applied to the motor windings after AC is removed is known as. It can be used even if out of sight of the machine provided it fulfills all the motor disconnecting requirements of the NEC and his industrial shop has written safety procedures. The controller disconnecting means 430102A can serve as the disconnecting means for the motor if the disconnect is located in sight from the motor location 430102B2.

When there is a wide variation in both torque and speed requirements such as a blower or hoist use a _____. The code requirements for motor disconnects are covered in. The code requirements for motor disconnects are covered in.

A listed molded-case switch. 2 Connectors listed as grounding and bonding equipment. The horsepower rating is actually for the motor of the appliance yet it raises a concern.

Motor disconnects are more than simple on-off devices to satisfy lockout-tagout requirements. After recently undergoing UL-508 testing a line of miniature rail-mountable devices with ratings as high as 60A now qualify as manual motor controllers suitable for use as motor disconnects. CSA code rule 28-604 3 a states.

The testing which lasted nearly a year covered all the tests for temperature overload endurance dielectric voltage withstand and short circuit response. Hermetic refrigerant motor compressors in air-conditioning or refrigerating equipment shall be provided with overload. The name of the motor part that rotates during operation is the _____.

The disconnect that is provided to meet the requirements of 430102A can also serve as the disconnect for the motor if it is located within sight from and not at a distance greater than 15 m 50 ft from the motor and equipment.


Stumped By The Code February 2011 Ec M


Disconnecting Means For Motor And Air Conditioning Equipment Iaei Magazine


Disconnecting Means For Motor And Air Conditioning Equipment Iaei Magazine